{"id":4035,"date":"2023-07-20T13:03:51","date_gmt":"2023-07-20T09:03:51","guid":{"rendered":"https:\/\/www.emprochem.com\/?post_type=product&#038;p=4035"},"modified":"2025-06-24T17:22:09","modified_gmt":"2025-06-24T13:22:09","slug":"zerust-inhibitor-fusion-zif-tape","status":"publish","type":"product","link":"https:\/\/www.emprochem.com\/index.php\/product\/zerust-inhibitor-fusion-zif-tape\/","title":{"rendered":"ZERUST\u00ae INHIBITOR FUSION (ZIF) TAPE"},"content":{"rendered":"<section class=\"main\">\n<div class=\"container\">\n<div class=\"row\">\n<div class=\"col-md-12 main-body\">\n<div class=\"pf-responsive\">\n<div class=\"catalog-product-details\">\n<div class=\"row product-description\">\n<div class=\"col-sm-12\">\n<h3>THE PROBLEM<\/h3>\n<p>Corrosion Under Insulation (CUI) is one of the (petro) chemical processing industries worst problems and the costs associated to mitigating it are astronomical.<\/p>\n<p>CUI is any type of corrosion that occurs due to a moisture buildup on the external surface of insulated equipment. If undetected, the results of CUI can lead to the shutdown of a process unit or an entire facility, and in rare cases it may lead to a process safety incident. While carbon and low- alloy steels operating between \u201345\u00b0C and 149\u00b0C are most at risk from CUI, the intermittent boiling and flashing that occurs above a metal temperature of 100\u00b0C (212\u00b0F) produces a fairly aggressive CUI environment. CUI is one of the most difficult processes to prevent. The reason for that is, by and large, no matter the precautions taken, water invariably seeps into the insulation and begins its dirty work\u2014sometimes unseen until process leakage occurs.<\/p>\n<p>&nbsp;<\/p>\n<h3>THE SOLUTION<\/h3>\n<p>Zerust has developed the unique Zerust Inhibitor Fusion (ZIF) tape using the proven platform of high temperature self-fusing silicone tapes to deliver corrosion inhibitors to the surface of the pipe lengths under insulation. The ZIF tape is simply wrapped over the pipe to be protected, over the existing coating, prior to the installation of the thermal insulation. Once installed, the inhibitors are most effective when there is moisture present and therefore mitigate corrosion caused by condensation and high temperature flashing. The unique inhibitors are effective to temperatures up to 200\u00b0C. When moisture evaporates as the pipeline temperatures rise, the inhibitor is released to be redeposited under the silicone tape and in contact with the pipeline where it is dormant untill the temperatures drop and moisture re-condenses.<\/p>\n<p>&nbsp;<\/p>\n<h3>PRODUCT DESCRIPTION<\/h3>\n<p>ZIF Tape is a corrosion inhibiting tape based on silicone elastomers with proprietary Zerust chem- istry integrated into the matrix. It combines Zerust\u2019s proven corrosion protection benefits with the specific properties of a self-fusing film for easy, cold application. It is stable under prolonged exposure to UV\/sunlight and is translucent in appearance. It is non-tacky to the touch, but will \u2018fuse\u2019 within ~30 seconds to form a long lasting bond. It is elastic in nature and can be stretched to provide closer fits to surfaces to which it is applied. This close fit coupled with the application tension minimizes the gaps\/spaces where moisture might penetrate.<\/p>\n<p>&nbsp;<\/p>\n<h3>ZIF TAPE BENEFITS<\/h3>\n<ul>\n<li>Active inhibitor protection system that mitigates corrosion when moisture is present<\/li>\n<li>Long term protection at minimal cost<\/li>\n<li>Easy to install<\/li>\n<li>Easy to remove with no residues<\/li>\n<li>Minimal\/no surface preparation required<\/li>\n<li>No heat or special equipment required for installation<\/li>\n<li>Wide temperature range of application -45\u00b0C to 200\u00b0C (-49\u00b0F to 392\u00b0F).<\/li>\n<li>Bonds to itself and remains non-tacky to the touch<\/li>\n<li>Can be used for low pressure leak prevention<\/li>\n<li>Good mechanical and puncture resistance\u2013 will protect paint underneath<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>TEST RESULTS<\/h3>\n<p><strong>Control:<\/strong><\/p>\n<p>Pipe coated with red iron oxide primer with a 2 inch bare\/uncoated section in the middle. Wrapped with 1 inch thick fiberglass insulation and tape.<\/p>\n<p><strong>Test Specimen:<\/strong><\/p>\n<p>Pipe coated with red iron oxide primer with a 2 inch bare\/uncoated section in the middle. Wrapped with ZIF tape (~50% overlap on the wraps).<br \/>\nWrapped with 1 inch thick fiberglass insulation and tape.<\/p>\n<p><strong>Test Conditions:<\/strong><\/p>\n<p>Step 1: Control and test specimens immersed in tap water for 8 hours<br \/>\nStep 2: Control and test specimens drained and placed in a convection oven at 80\u00b0C overnight Steps 1 and 2 carried out daily for 25 days<\/p>\n<p><strong>Results:<\/strong><\/p>\n<p>The ZIF tape significantly reduced the corrosion rate to both the bare and the coated sections even through the extreme test protocols. Substantial corrosion was seen in the control with blistering and delamination of the primer layer. The most effective method of preventing CUI is to keep water and electrolytes from coming into contact with the unprotected metal surface. However, while it\u2019s nearly impossible to guarantee that the insulation or coating will not be breached \u2013 and none of the above mitigation practices guarantee the complete prevention of CUI \u2013 Zerust\u2019s ZIF tape works with the assumption that there will be moisture ingress and actively inhibits corrosion.<\/p>\n<p>&nbsp;<\/p>\n<h3>AVAILABILITY<\/h3>\n<p>Available in 36 ft. long, individual, whole rolls in 2\u201d, 4\u201d, 12\u201d and 16\u201d widths.<\/p>\n<p>Part No.<\/p>\n<ul>\n<li>02\u201d ZIF Tape: 250-F-00105<\/li>\n<li>04\u201d ZIF Tape: 250-F-00108<\/li>\n<li>12\u201d ZIF Tape: 250-F-00106<\/li>\n<li>16\u201d ZIF Tape: 250-F-00107<\/li>\n<\/ul>\n<p>ZIF Tape 36 ft. long<\/p>\n<p>&nbsp;<\/p>\n<p><a class=\"btn btn-primary\" href=\"https:\/\/www.zerust-oilgas.com\/documents\/brochures\/ZIF-Tape_CUI.pdf\" target=\"_blank\" rel=\"noopener\">DOWNLOAD BROCHURE<\/a><\/p>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"aside-bottom2\">\n<div class=\"container\">\n<div class=\"theme-blank module-static-content-001\">\n<div class=\"module\">\n<div class=\"module-content\">\n<div class=\"grid contact-grid\">\n<div class=\"grid-item left\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<h2>HISTORICAL DATA SHOWS THAT ABOUT 60% OF PIPE LEAKS ARE CAUSED BY CORROSION UNDER INSULATION (CUI).<\/h2>\n<p>Available in 36 ft. long, individual, whole rolls in 2\u201d, 4\u201d, 12\u201d and 16\u201d widths.<\/p>\n<div class=\"embeddedContent\" data-align=\"left\" data-maxheight=\"315\" data-maxwidth=\"700\" data-oembed=\"https:\/\/vimeo.com\/803529023\/2e39081618\" data-resizetype=\"responsive\"><iframe loading=\"lazy\" title=\"Zerust Inhibitor Fusion (ZIF) Tape for CUI - Animation\" src=\"https:\/\/player.vimeo.com\/video\/803529023?h=2e39081618&amp;app_id=122963\" width=\"426\" height=\"240\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\" data-mce-fragment=\"1\"><\/iframe><\/div>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":4039,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[15],"product_tag":[],"class_list":["post-4035","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-uncategorized"],"_links":{"self":[{"href":"https:\/\/www.emprochem.com\/index.php\/wp-json\/wp\/v2\/product\/4035","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.emprochem.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.emprochem.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.emprochem.com\/index.php\/wp-json\/wp\/v2\/comments?post=4035"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.emprochem.com\/index.php\/wp-json\/wp\/v2\/media\/4039"}],"wp:attachment":[{"href":"https:\/\/www.emprochem.com\/index.php\/wp-json\/wp\/v2\/media?parent=4035"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.emprochem.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=4035"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.emprochem.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=4035"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}